Información sobre equipo

Tektronix DC 510 Contador
Fabricante:
Tektronix
Modelo: DC 510
Fecha: 1981
Categoría: Los instrumentos de medición
Grupo: Contador
Descripción: Universal Counter/Timer
Información:
                                    Instrument Description

The TEKTRONIX DC 510 is a universal counter/timer plug-in.
It features reciprocal Frequency, Period, Ratio, and Events
B During A measurements to 350 MHz. For timing measurements,
the Time Interval, Width, Risetime and Falltime functions
feature 3.125 nsec single-shot resolution. For these
measurements, averaging and identical A and B channels
provide increased accuracy. Also included is a time manual
mode, as well as three 350 MHz Totalize modes (A, A+B, and
A-B). The DC 510 also has an auto-trigger feature, a
probe-compensation feature, an auto averages function, and
an extensive set of automatic power-up self tests.
The DC 510 has a DVM mode that reads out the channel A and
channel B trigger level voltages. Shaped outputs and an
arming input are available at the front panel. Also
available at the front panel is a signal for use with the
probe compensation function.
The DC 510 can be equipped with an optional,
oven-controlled, 10 MHz crystal oscillator to obtain an even
more stable and precise internal time base.
A GPIB conversion kit (Field Modification Kit 040-1023-00)
for the DC 510 is available from Tektronix, Inc.

Estos manuales están disponibles para el equipo anterior:

Tipo de Manual:: Servicio y Manual del usuario Tektronix-10045-Manual-Page-1-Picture
Páginas:: 153
Tamaño:: 37.97 Mbytes (39809916 Bytes)
Idioma: Inglés
Revisión: revised
Número de identificación: 070-3552-01
Fecha: 01 octubre 1981
Calidad: Documento Scaned, todo legible.
Añadir fecha:
MD5: 5d625564efe7b52773087590803e9616
Descargas: 13 desde 30 diciembre 2017
Información:
LIST OF ILLUSTRATIONS........................................iii

LIST OF
TABLES......................................................iii

OPERATORS SAFETY SUMMARY..........................iv

SERVICE SAFETY SUMMARY..................................v

Section 1 SPECIFICATION

Instalment Description..................1-1

Instrument Options......................1-1

Standard Accessories..................1-1

Performance Conditions..............1-1

Safety Certification......................1-1

Electrical Characteristics..............1-2

Miscellaneous..............................1-12

Environmental..............................1-12

Physical Characteristics................1-13

Section 2 OPERATING INSTRUCTIONS

Introduction........................................2-1

First Time Inspection....................2-1

Repackaging for Shipment..........2-1

Operating and Non-Operating

Environments................................2-1

Preparation For Use..........................2-1

Rear Interface Considerations...	2-1

Installation and Removal..............2-1

Front Panel Operation............................2-3

Front Panel Display..........................2-3

Display..........................................2-3

Front Panel Controls........................2-3

Front Panel Connectors....................2-3

Front Panel Push Buttons................2-5

Operators Familiarization......................2-7

Introduction........................................2-7

General Operating Characteristics 2-7

Self Test Display..........................2-7

Input Considerations........................2-8

Maximum Safe Input Voltage

Limits......................‘2-8

Connecting External and Internal

Signal Sources..............................2-8

Measurement Considerations............2-8

Input Coupling, Noise, and

Attenuation..................................2-8

Triggering the Counter..................2-9

Reducing Measurment Errors ...	2-9

Measurement Examples....................2-11

Frequency A and Period A..........2-11
Page
Section 2 OPERATING INSTRUCTIONS (cont)

Ratio B/A......................................2-11

Width A and Time A - B (Time

Interval)........................................2-11

Null................................................2-12

Events B During A........................2-12

Time Manual................................2-12

Totalize A......................................2-12

Totalize A+ B................................2-13

Totalize A-B................................2-13

Risetime A and Falltime A............2-13

Probe Compensation....................2-14

Test Function................................2-14

Arming (ARM Input)......................2-15
WARNING
THE FOLLOWING SERVICING INSTRUCTIONS ARE FOR USE BY
QUALIFIED PERSONNEL ONLY. TO AVOID PERSONAL INJURY, DO NOT
PERFORM ANY SERVICING OTHER THAN THAT CONTAINED IN OPERATING
INSTRUCTIONS UNLESS YOU ARE QUALIFIED TO DO SO.
Section 3 THEORY OF OPERATION

Block Diagram Description.......... 3-1

Detailed Circuit Description.......... 3-3
Section 4 CALIBRATION

Performance Check Procedure..............4-1

Introduction..................................4-1

Calibration Interval........................4-1

Service Available..........................4-1

Test Equipment Required............4-1

Preliminary Control Settings..............4-3

Adjustment Procedure............................4-15
CALIBRATION (cont)

Introduction..................................4-15

Test Equipment Required............4-15

Preliminary Control Settings..............4-15

Preparation..................................4-15

MAINTENANCE

Static-Sensitive Components ...	5-1

Test Equipment............................5-1

Circuit Board Removal and

Replacement................................5-1

Magnetic Latch Relays................5-3

Cleaning Instructions....................5-4

Obtaining Replacement Parts ...	5-4

Ordering Parts..............................5-4

Soldering Techniques....................5-4

Interconnecting Pins....................5-5

Square Pin Assemblies................5-5

Bottom Entry and Side Entry

Circuit Board Pin Sockets............5-5

Multipin Connectors......................5-5

Rear Interface Connectors....................5-7

Introduction..................................5-7
Functions Available at Right Rear

Interface Connector (P1600)____ 5-7

Functions Available at Left Rear Interface Connector
(P1820)---- 5-8
Section 5 MAINTENANCE (cont)

Diagnostics....................

Introduction.................

Equipment Required..........

Adjustment and Test Point

Locations...................

Self Test....................

TEST Function...............

Troubleshooting................

Signature Analysis..............

Introduction.................

Internal Signature Analysis.....

Kernel Signature Analysis......

Selected Components (R1307 and R1326).....................
Section 6 OPTONS

Option 01........................

Section 7 REPLACEABLE ELECTRICAL PARTS 
Section 8 DIAGRAMS AND ILLUSTRATIONS 
Section 9 REPLACEABLE MECHANICAL PARTS
Tektronix-10045-Manual-Page-1-Picture


Comments (0)

No comments yet. Be the first!

Add Comment

* Required information
1000
Captcha Image
Powered by Commentics