Equipment information

Fluke 433 Analyzer
Manufacturer:
Model:
433
Date:
2007
Category:
Group:
Description:
Three Phase Power Quality Analyzer

Information

The Fluke 433, 434, 435 Three Phase Power Quality Analyzer offers an extensive and powerful set of measurements to check power distribution systems.

show more

Service Manual
Manual Type:
Service Manual
Pages:
74
Size:
1.06 Mbytes (1110428 Bytes)
Language:
english
Revision:
1
Manual-ID:
4822 872 05396
Date:
2007 05 01
Quality:
Electronic document, no scan, very well readable.
Upload date:
2017 08 10
MD5:
d33e3648e122b794584d5ea52b5d92e2
Downloads:
1470

Information

Limited Warranty & Limitation of Liability ... ii Introduction and Safety Instructions ... 1-1 1.1 Introduction to Manual ... 1-3 1.2 Safety ... 1-3 1.2.1 Introduction ... 1-3 1.2.2 Safety Precautions ... 1-3 1.2.3 Caution and Warning Statements ... 1-3 1.2.4 Symbols ... 1-4 1.2.5 Impaired Safety ... 1-4 1.2.6 General Safety Information ... 1-4 Specifications ... 2-1 2.1 Introduction ... 2-3 2.2 Electrical Measurements ... 2-4 2.3 Wiring Combinations ... 2-13 2.4 General ... 2-13 2.5 Mechanical ... 2-14 2.6 Power ... 2-14 2.7 Standards ... 2-14 2.8 Cross talk ... 2-15 2.9 Common Mode Rejection Ratio (CMRR) ... 2-15 2.10 Safety ... 2-15 2.11 Environmental ... 2-15 2.12 Printers and Interface ... 2-16 2.13 Electro Magnetic Compatibility (EMC) ... 2-16 Performance Verification ... 3-1 3.1 Introduction ... 3-3 3.2 Equipment Required for Verification ... 3-4 3.3 Relation between Characteristics and Performance Test. ... 3-4 3.4 General Instructions ... 3-5 3.5 Operating Instructions ... 3-5 3.6 Display and Backlight Test ... 3-5 3.7. Verification of Current Inputs ... 3-7 3.7.1 Preparation ... 3-7 3.7.2 Accuracy ... 3-7 3.7.2 Bandwidth check of current channels (*) ... 3-8 3.8 Voltage Inputs ... 3-8 3.8.1 Introduction ... 3-8 3.8.2 Verification of voltage inputs in 120 V range ... 3-10 3.8.3 Verification of voltage inputs in 230 V range ... 3-11 3.8.4 Verification of voltage inputs in 400 V range ... 3-13 3.8.5 Verification of voltage inputs in 6 kV range (Transients) ... 3-15 3.9 Channel Isolation (*) ... 3-17 Calibration Adjustment ... 4-1 4.1 General ... 4-3 4.1.1 Introduction ... 4-3 4.1.2 Calibration number and date ... 4-3 4.1.3 General instructions ... 4-4 4.1.4 Equipment required for calibration ... 4-4 4.2 Calibration Procedure Steps ... 4-4 4.3 Starting The Calibration ... 4-5 4.4 Contrast Calibration Adjustment ... 4-7 4.5 Warming Up ... 4-8 4.6 Final Calibration ... 4-9 4.6.1 Offset adjustment ... 4-9 4.6.2 Low voltage and current gain adjustment ... 4-10 4.6.3 Voltage gain adjustment ... 4-10 4.7 Save Calibration Data And Exit ... 4-12 Disassembling the Analyzer ... 5-1 5.1. Introduction ... 5-3 5.2. Disassembly & Reassembly Procedures ... 5-3 5.2.1 Required Tools ... 5-3 5.2.2 Removing the Tilt Stand & Hang Strap ... 5-3 5.2.3 Replacing the Side-Strap, Changing the Side-Strap Position ... 5-4 5.2.4 Opening the Analyzer, Removing the Battery ... 5-4 5.2.5 Removing the Main PCA Unit ... 5-6 5.2.6 Removing the Display Assembly ... 5-7 5.2.7 Replacing the LCD Window/Decal ... 5-8 5.2.8 Removing the Keypad and Keypad Foil ... 5-8 5.2.9 Disassembling the Main PCA Unit ... 5-8 5.2.10 Reassembling the Main PCA Unit ... 5-9 5.2.11 Reassembling the Analyzer ... 5-9 List of Replaceable Parts ... 6-1 6.1 Introduction ... 6-3 6.2 How to Obtain Parts ... 6-3 6.3 Service Centers ... 6-3 6.4 Final Assembly Parts ... 6-4 6.5 Main PCA Unit Parts ... 6-6 6.7 Accessories ... 6-7

show more