Equipment information:

Tektronix 2230 Oscilloscope
Manufacturer:
Tektronix
Model: 2230
Date: 1985
Category: Measurement instruments
Group: Oscilloscope
Description: Digital Storage Oscilloscope
Information:
                                    INTRODUCTION!

The TEKTRONIX 2230 Oscilloscope! is a combination nonstorage
and digital storage dual-channel 100 MHz bandwidth instrument.
It is a rugged, lightweight oscilloscope featuring
microprocessor operation and alphanumeric crt readout
of many of the front-panel controls. In the digital
storage mode, up to three waveform sets (CH 1 and/or CH 2)
may be stored in a SAVE REF memory and recalled for
display at a later time. The vertical system provides
calibrated deflection factors from 2 mV per division
to 5 V per division. The horizontal system provides
calibrated sweep speeds from 50 ns per division to 0.5 s
per division for nonstorage mode with three slower
sweep speeds (1 s, 2 s, and 5 s per division) added
for store mode operation. A X10 magnifier extends
the maximum sweep speed to 5 ns per division.

The digital storage sampling rate is 20 megasamples
per second maximum, and the acquired record length is
4K samples (1K may also be selected) for a single
channel or 2K samples for dual-channel (CHOP or ALT)
displays. Any contiguous 1K sample of an acquired record
is displayable. The fast sampling rate can capture a
glitch with a pulse width of at least 100 ns. A 4K
compress feature enables a 4K record length acquisition
to be compressed to 1K in length for ease in viewing or
storing in the SAVE REF memory. If compression is not
desired, all 4K or any 1K portion of a 4K record may be
stored in the SAVE REF memory. The SAVE store mode stops
the waveform acquisition in progress, allowing a particular
display to be stored or examined before further acquisitions
cause a waveform update.
Cursors may be used to obtain voltage measurements,
time difference measurements, and delay-time measurements
on any of the store mode waveform displays. Delta
volts, delay time, delta time, and 1/delta time (either
delta time or 1/delta time is selectable via the MENU)
are displayed in the crt readout for ease in obtaining
precise measurement results. The cursors are positioned
to any displayed store mode waveform to make measurements.
An alternate use of the cursor-positioning control is
to horizontally position the 1K display window to
any location within a 4K record length waveform
acquisition. The displayed portion of a 4K acquisition
is stored when the SAVE REF feature is used.

These manuals are available for the above equipment:

Tektronix -- 2230 -- User Manual
File name: Tektronix-2519-Manual-Page-1-Picture
Manual Type: User Manual
Pages: 188
Size: 12.25 Mbytes (12845836 Bytes)
Language: english
Revision: Revised
Manual-ID/Number: 070-4998-02
Date: May 1988
Quality: Scanned document, all readable.
Upload date:
MD5: 0f25629be9d385fe183dbac5d60acc5b
ed2kID: 129ad9f2211c7979a50714c42b46db66
Downloads: 1126 since 13 June 2011
Information:
Tektronix-2519-Manual-Page-1-Picture
Start Free Download


Tektronix -- 2230 -- Service and User Manual
File name: Tektronix-4506-Manual-Page-1-Picture
Manual Type: Service and User Manual
Pages: 472
Size: 53.53 Mbytes (56125048 Bytes)
Language: english
Revision: Revised
Manual-ID/Number: 070-4999-00
Date: May 1987
Quality: Scanned document, reading partly badly, partly not readable.
Upload date:
MD5: 7c8d70835a74c043395ecc5d8fe9babb
ed2kID: 5f38fae4d46aea51683c82567485026a
Downloads: 2910 since 25 April 2013
Information:
Tektronix-4506-Manual-Page-1-Picture
Start Free Download


Comments

No comments yet.

Add Comment

* Required information
(never displayed)
 
Bold Italic Underline Strike Superscript Subscript Quote Line Bullet Link Email Image Video
 
Smile Sad Huh Laugh Mad Tongue Crying Grin Wink Scared Cool Sleep Blush Unsure Shocked
 
1000
Enter the word hand backwards.
 
Enter answer:
 
Notify me of new comments via email.
 
Remember my form inputs on this computer.
 
 
Powered by Commentics