Geräte Informationen:

Hickok Electrical Instrument Company 203PR Analog Multimeter
Hersteller:
Hickok Electrical Instrument Company
Modell: 203PR
Datum: 1947
Kategorie: Messgeräte
Gruppe: Analog Multimeter
Beschreibung: Volt Ohm Capacity Milliammeter
Informationen:
                                    The Hickok Electronic Volt-Ohm-Capacity-Mllliammeter,
Model 203PR, is a compact universal test Instrument
which may be used in making measurements in the study
of radio and electrical circuits. It is a versatile
Instrument as the measurement of wide ranges of d.c.
currents, a.c. and d.c. voltages, resistances, capacitances
and inductances may all be made by the one unit. Built
under Hickok high standards of workmanship, It is an
accurate and durable test Instrument.

Folgende Anleitungen sind für obiges Gerät verfügbar:

Hickok Electrical Instrument Company -- 203PR -- Serviceanleitung, nur Schaltplan
Dateiname: Hickok-3864-Manual-Page-1-Picture
Dokumenttyp: Serviceanleitung, nur Schaltplan
Seitenanzahl: 21
Dateigröße: 2.28 Mbytes (2389983 Bytes)
Sprache: Englisch
Revision:
Dokument-ID/Nummer:
Datum: 24 November 1947
Qualität: Gescanntes Dokument, teilweise schwer oder teilweise nicht zu lesen.
Upload Datum:
MD5: ab22272f0bce28dd36d981659ca17cdb
ed2kID: 5e8aff9bdf1cb122273cf484b6263125
Downloads: 190 seit 07 Januar 2013
Informationen:
SECTION 1 - DESCRIPTION

1.1	Purpose	3

1.2	Description	3

a.	Physical	3

b.	Components	3

c.	Functional	3

d.	Electrical	3

SECTION 2 - THEORY

2.1	General	4

2.2	Bridge Circuit	4

2.3	A.C. Voltmeter	4

2.4	D.C. Voltmeter	4

2.5	Ohmmeter ...	5

2.6	Capacity and Inductance Measurements	5

a.	Capacity

b.	Inductance

SECTION 3 - OPERATION

3.1	General	5

3.2	A.C. Voltage Measurements	5

3.3	D.C. Voltage Measurements	6

3.4	Current Measurements	6

3.5	Resistance Measurements	6

3.6	Capacitance Measurements	6

3.7	Inductance Measurements	7

3.8	Decibel Measurements	7

SECTION 4 - APPLICATION

4.1	General	9

4.2	D.C. Voltmeter	9

a.	Input Impedance	9

b.	RF-IF Circuits	9

c.	Oscillation Check	9

d.	Discriminator Circuit Alignment	9

4.3	A.C. Voltmeter	9

4.4	Ohmmater	10

4.5	Capacity Measurements	10

SECTION 5 - MAINTENANCE

5.1	General	10

5.2	Vacuum Tubes	10

5.3	Dry Cells	10

5.4	Capacity and Resistance Measurements	10

SECTION 6 - PARTS LIST

Par La LI at for Model 203-S0Î3PR	15 & 16
Hickok-3864-Manual-Page-1-Picture
Kostenlos herunterladen


Kommentare

Noch keine Kommentare vorhanden.

Kommentar Hinzufügen

* Pflichtfeld
(wird nicht veröffentlicht)
 
Bold Italic Underline Strike Superscript Subscript Quote Line Bullet Link Email Image Video
 
Smile Sad Huh Laugh Mad Tongue Crying Grin Wink Scared Cool Sleep Blush Unsure Shocked
 
1000
What is the next number: 10, 12, 14, ..?
 
Die Antwort lautet:
 
Informiere mich via E-Mail über neue Kommentare.
 
Meine Daten auf diesem Computer.
 
 
Powered by Commentics