Geräte Informationen:

Sorensen Company DCR-80-6B Netzteil
Hersteller:
Sorensen Company
Modell: DCR-80-6B
Datum: 1977
Kategorie: Messgeräte
Gruppe: Netzteil
Beschreibung: 500W Power Supply
Informationen:
                                    Designed for either bench or rack use, the typical DCR-B
power supply provides a highly regulated, precise d-c
output, adjustable over a wide range. It operates from
a nominal 115 Vac (208/220/230-Vac inputs are available
as options) and exhibits a rapid response to transients,
both load and line.

Folgende Anleitungen sind für obiges Gerät verfügbar:

Sorensen Company -- DCR-80-6B -- Service- und Bedienungsanleitung
Dateiname: Sorensen-3829-Manual-Page-1-Picture
Dokumenttyp: Service- und Bedienungsanleitung
Seitenanzahl: 60
Dateigröße: 3.04 Mbytes (3190742 Bytes)
Sprache: Englisch
Revision:
Dokument-ID/Nummer:
Datum: 10 Mai 1977
Qualität: Gescanntes Dokument, alles ist lesbar.
Upload Datum:
MD5: 1369c2b915c0bc0448dd0af85e6cb9ae
ed2kID: aed2d88886ac408ff0d2d921728c3656
Downloads: 723 seit 31 Dezember 2012
Informationen:
	
1. INTRODUCTION AND DESCRIPTION		
		
1.1	Introduction..............	...1-1
1.2	Description...............	...1-1
1.3	Optional Modifications....	...1-3
1.4	Accessory OVP.............	...1-3
		
2. PREPARATION FOR USE		
		
2.1	General...................	...2-1
2.2	Initial Inspection........	...2-1
2.3	Electrical Installation...	...2-1
2.4	Mechanical Installation...	...2-2
2.5	Electrical Check..........	...2-2
		
3. OPERATING INSTRUCTIONS		
3.1	General...................	...3-1
3.2	Voltage-Mode Operation....	...3-1
3.3	Current-Mode Operation....	...3-5
3.4	Parallel Operation........	...3-7
3.5	Series Operation..........	. ..3-9
3.6	Unit-Shutdown Circuit.....	3-14
4.1	Introduction..............	...4-1
4.2	Phase-Control Principle...	...4-1
4.3	Block-Diagram Analysis----	...4-3
4.4	Detailed Circuit Description.4-3	
		
MAINTENANCE		
		
5.1		...5-1
5.2	Periodic Servicing........	...5-1
5.3	Troubleshooting...........	...5-1
5.4	Calibration...............	...5-1
5.5	Performance Testing.......	...5-3
		
DRAWINGS AND PARTS LISTS		
		
6.1		...6-1
6.2	Parts List Column	
	Headings Defined..........	6-1
OVERVOLTAGE (OVP) ACCESSORY (MS		OPTION)
		
7.1		. ..7-1
7.2	Installation..............	...7-1
7.3	OVP Adjustment............	...7-2

This manual contain; operation and maintenance data on the 500-watt units of the DCR-B series Sorensen Power Supplies. It is intended to familiarize the user with the functioning of the unit, to introduce the varied applications to which the unit may be adapted, and to furnish sufficient maintenance data to assure long operating life.

Seven major sections form the manual divisions. Section
1 contains a brief functional description of the DCR-B
series power supplies. Initial inspection and checkout
procedures are outlined in section 2. Operating instructions,
including methods for adapting units to various applications,
comprise section 3. Sections 4 and 5 provide the principles
of operation and maintenance procedures respectively.
System drawings and the replacement parts list are provided
in section 6. Concluding the manual, section 7 describes
the DCR-B OVP (overvoltage protector) accessory M5.
Sorensen-3829-Manual-Page-1-Picture
Kostenlos herunterladen


Kommentare

Noch keine Kommentare vorhanden.

Kommentar Hinzufügen

* Pflichtfeld
(wird nicht veröffentlicht)
 
Bold Italic Underline Strike Superscript Subscript Quote Line Bullet Link Email Image Video
 
Smile Sad Huh Laugh Mad Tongue Crying Grin Wink Scared Cool Sleep Blush Unsure Shocked
 
1000
Is it true or false that green is a number?
 
Die Antwort lautet:
 
Informiere mich via E-Mail über neue Kommentare.
 
Meine Daten auf diesem Computer.
 
 
Powered by Commentics