Equipment information:

Advance Instruments OS250 Oszilloskop
Advance Instruments
Model: OS250
Date: 1974
Category: Messgeräte
Group: Oszilloskop
Description: 10MHz dual trace oscilloscope
                                    The Advance OS250 Oscilloscope is a 10 MHz dual trace
instrument with a 10cm x 8cm display. It is designed
for use in general purpose laboratory work, educational
uses, TV and servicing applications.

It features two identical input channels with a maximum
sensitivity of 5mV/cm and a bandwidth of DC to 10MHz.
The two channels may be viewed separately, alternately
at fast timebase speeds, or chopped at a 250kHz rate at
low timebase speeds.

Particular attention has been paid to trigger performance,
and the system used includes a variable control with
bright line operation in the absence of a signal,
or when the trigger level is outside the range of
the input signal.

these manuals are available for the above equipment:

Manual Type: Service- und Bedienungsanleitung Advance-3823-Manual-Page-1-Picture
Pages: 37
Size: 5.43 Mbytes (5693414 Bytes)
Language: Englisch
Quality: Gescanntes Dokument, alles ist lesbar.
Upload date:
MD5: 25a1a4bca32d7b2877973999d853fcaa
Downloads: 618 seit dem 31 Dezember 2012

Manual Type: Schaltplan Advance-9410-Manual-Page-1-Picture
Pages: 5
Size: 1.28 Mbytes (1341433 Bytes)
Language: Englisch
Date: 01 Januar 1974
Quality: Gescanntes Dokument, sehr gut lesbar.
Upload date:
MD5: c04a522e9a75c6fb6e9fd0710eb4ce0d
Downloads: 40 seit dem 26 August 2017
Uploaded by: Alex
Info Note: All the schematics with good quality.

Comments (1)

Topic: Advance Instruments OS250
0/5 (0)
OS250 user
Apr 2016
First Poster
OS250 user says...
Many thanks for the uploader, site creator and maintenance team! :)

My oscilloscope

This is my only oscilloscope, and im depending on him to do my school project. He always have been a got buddy, but now need some service.. and this manual are a great help!
So far im i see that the Diode bridge (MR301) are not rectifying well.. he are producing a AC current on output, and the DC tension is about 30V (instead 155V, even if i adjust R320). But after i replace a Diode Bridge by a new "2W08", after a couples os seconds i have a drop of tension across C315 (155V to 60V).. i need to troubleshoot a little more, but maybe is the C315, TR301 or TR302 that are not healthy.. we will see :)

have a good day everyone! and thanks again!
Page 1 of 1

Add Comment

* Required information
Captcha Image
Powered by Commentics